createProcessFlowModuleCommand =  OMBCREATE ( PROCESS_FLOW_MODULE 
          "QUOTED_STRING" [ SET ( "setPropertiesClause" [ SET 
          "setReferenceClause" ] | "setReferenceClause" ) ] )
     setPropertiesClause =  PROPERTIES "(" "propertyNameList" ")" VALUES "(" 
          "propertyValueList" ")"
     setReferenceClause =  ( "setReferenceLocationClause" [ SET 
          "setReferenceIconSetClause" ] | "setReferenceIconSetClause" )
     propertyNameList =  "UNQUOTED_STRING" { "," "UNQUOTED_STRING" }
     propertyValueList =  "propertyValue" { "," "propertyValue" }
     setReferenceLocationClause =  ( REFERENCE | REF ) LOCATION "QUOTED_STRING"
     setReferenceIconSetClause =  ( REFERENCE | REF ) ICONSET "QUOTED_STRING"
     propertyValue =  ( "QUOTED_STRING" | "INTEGER_LITERAL" | 
          "FLOATING_POINT_LITERAL" )
Base properties for PROCESS_FLOW_MODULE: Name: BUSINESS_NAME Type: STRING(200) Valid Values: Any valid character string in supported character set. Default: NAME Business name of a Process Flow Module Name: DESCRIPTION Type: STRING(4000) Valid Values: Any valid character string in supported character set. Default: Empty string Description of a Process Flow Module
Table 9-49 PROCESS_FLOW_MODULE Object
| Property | Type | Choices | Min | Max | Default | Description | 
|---|---|---|---|---|---|---|
| 
 DB_LOCATION  | 
 STRING  | 
 none  | 
 none  | 
 none  | 
 empty string  | 
 This value indicates the location where generated code will be deployed to.  | 
| 
 EVAL_LOCATION  | 
 STRING  | 
 none  | 
 none  | 
 none  | 
 empty string  | 
 The location in which the process flow will be evaluated.  |